Coolant level drops 20 minutes after chiller is installed and activated on Magnus 400


Product

 
  • Magnus™ 400
  • Magnus 400 Xpose

Component

 
  • Flow tube
  • CPC ports
  • Chiller

Symptoms

 

About 20 minutes after you install and turn on the chiller, the coolant level drops.


Cause

 

Coolant is leaking.


Solution

 
  1. Turn off the device and disconnect the power.
  2. Check for coolant leakage around the flow tubes.
  3. If a tube is wet, replace it, and wipe up all leaked coolant.
  4. Turn on the device and check again for coolant leakage.
  5. If the flow tube is still wet, replace the relevant CPC port on the LDA head.
  6. Turn on the device and check again for coolant leakage.
  7. If there is still leakage, look inside the chiller for leakage.
  8. If there is leakage, replace the chiller.