The focus stepper motor value is according to plate type. Perform the
focus calibration test procedure for each plate type and thickness that
the customer uses.
- Load a plate.
- From the Kodak Xpo palette, select Tools >
Calibration.
Note: The Plate Thickness parameter of the loaded plate
is automatically transferred from the Lotem/Magnus 400 Controller software.
- In the Calibrate dialog box, perform the following steps:
- In the Calibration Type list, select Focus.
- In the Intensity for Test field, enter a relatively low
intensity valuefor example, 110.
Note: The higher the intensity, the more difficult it will
be to visually differentiate between the test strips and select
the best focus. To obtain best results, start with a value that
is 40% lower than the default value.
- In the Focus Value field, do not change this value
until the optimal focus value has been determined.
Note: To load the last-saved focus test value, click Get.
- In the Test Focus Values [steps] area, in the From
and To fields, type the test range for the focus stepper
motor values. For example, on 0.3-mm thick plates, enter a range
between 150 and 200 motor steps.
- In the Number of Steps list, select the number of exposures
to perform for the selected test focus value range. For best results,
enter a minimum of 10 steps.
When you type a step value, the Lotem/Magnus 400 Controller software
automatically calculates and displays the size of each step interval
in the Size field, using the following formula:
Step size = (ToFrom)/(Number of steps 1)
- In the Resoluton list, select the resolution used by the
customer.
- In the Test File list, select the TIF file that you want
to use for the focus test.
Note: Test files are predefined; the ones that appear in
the list are according to the selected resolution.
- In the Current Plate list, select the plate size that you
are using for the test.
- In the Image Offset fields, type a value in millimeters
for the horizontal offset (around the drum), and the vertical offset
(along the drum).
Note: The (0,0) offset coordinate is located at the upper-left
corner of the plate.
If you use the same plate for multiple tests, enter the appropriate
offset values for each test.
- In the Plate Policy section, select or clear the Load
and Unload check boxes that apply to focus test:
- Load: Automatically loads a new plate before the test
begins. To perform multiple calibration tests on the same plate,
before you start the next test, clear this check box to reuse
the plate.
- Unload: Automatically unloads the plate after the test.
To perform multiple calibration tests on the same plate, before
you start the next test, clear this check box.
- Click Test to start the focus test.
Lotem/Magnus 400 Controller performs a series of exposures on the plate,
after which you need to process the plate and examine the results.
- From the batch of exposed target strips, select the best strip:
- For positive plates (blue), select the clearest strip with the
lowest density.
- For negative plates (green), select the clearest strip with the
highest density.
- In the Focus Value field, type the optimal focus stepper motor
value, and click Save.
Note: If required, repeat the test for other plate types and
thicknesses.
|