This procedure includes the following sections:
Calibrating intensity
- Load a plate.
- From the Kodak Xpo palette, select Tools >
Calibration. The Plate Sensitivity parameters of the loaded
plate are automatically transferred from the Lotem/Magnus 400 Controller
software.
- In the Calibrate dialog box, perform the following steps:
- In the Calibration Type list, select Intensity.
- In the Intensity field, do not change this value
until the optimal laser intensity has been determined. See Setting
the optimal laser intensity and drum speed.
Note: To load the last-saved intensity test value, click
Get.
- In the Drum Speed field, type the number of revolutions
per minute (rpm) at which you want the drum speed motor to revolve,
or perform the test with the last-saved drum speed that appears
in this field.
Note: Accelerated drum speeds require higher intensities
than reduced/low drum speeds. The optimal drum speed is the drum
speed value that was used to obtain the optimal laser intensity.
See Setting the optimal laser intensity and drum speed.
- Clear the Calculate All Points When Saving check box. This
ensures that the working conditions are updated only for the resolution
that is currently defined.
- In the Test Intensity Values [mW] area, in the From
and To fields, type the test range for the laser intensity
stepper motor values. For best results, enter a range between 180
mW and 300 mW.
- In the Number of Steps list, select the number of exposures
to perform for the laser intensity test. For best results, enter
a minimum of 10 or 11 steps.
When you type a step value, the Lotem/Magnus 400 Controller software
automatically calculates and displays the size of each step interval
in the Size field, using the following formula:
Step size = (ToFrom)/(Number of steps 1)
Note: The interval value provides a quick reference for the
platesetter operator, and cannot be changed.
- In the Resoluton list, select the resolution used by the
customer.
- In the Test File list, select the TIF file that you want
to use for the drum speed test.
Note: Test files are predefined; the ones that appear in
the list are according to the selected resolution and plate type.
- In the Current Plate list, select the plate that you are
using for the test.
- In the Image Offset fields, type a value in millimeters
for the horizontal offset (around the drum), and the vertical offset
(along the drum).
Note: The (0,0) offset coordinate is located at the upper-left
corner of the plate.
If you use the same plate for multiple tests, enter the appropriate
offset values for each test.
- In the Plate Policy section, select or clear the Load
and Unload check boxes that apply to focus test:
- Load: Automatically loads a new plate before the test
begins. To perform multiple calibration tests on the same plate,
before you start the next test, clear this check box to reuse
the plate.
- Unload: Automatically unloads the plate after the test.
To perform multiple calibration tests on the same plate, before
you start the next test, clear this check box.
- Click Test to start the intensity test.
Lotem/Magnus Controller performs a series of exposures on the plate,
after which you need to process the plate and examine the results.
Selecting the optimal laser intensity and drum speed
- Visually examine the results, and select the target strip for which
the 50% dot area measures 50%.

Measure the density in the solid area. A good density reading should
be 0.07 dmin or less, as shown below.
When the intensity is too low, the black imaged lines are almost
invisible, while the non-imaged white lines are easily noticeable.
Likewise, when the intensity is too high, the black imaged lines are
easily noticeable, while the non-imaged white lines are less visible.

Low
intensity High
intensity
- In the Intensity field, type the optimal intensity value returned,
and click Save.
- Verify that the new value was saved in the database.
- In the Lotem/Magnus 400 Controller software, in the Hardware tree,
go to DataBase, and double-click Res Int.

- In the Resolution/Intensity Tables dialog box, locate the row
with the resolution and drum speed that you used for the test and,
in the Intensity column, the newly-saved value should appear.
- Click Close.
- If required, repeat the test for other resolutions used by the customer.
|