Replacing the air pressure filters on Magnus 800


Product

 

Magnus® 800


Background

 

There are three air pressure filters in the air pressure unit. The filters should be periodically inspected to make sure that they do not contain any water or oil and replaced every six months.


Procedure

 

Inspect the air pressure filters:

  1. Inspect the air filter window to make sure that the filter does not contain any water or oil:



    Note: Only applicable to the two air pressure filter units closest to the air gauge:
  2. To drain any water or oil that exists in the air pressure filter units, press the orange button, located at the bottom of the two filter units—closest to the air gauge:

Replace the air pressure filters:

  1. Turn the knob clockwise to close the air supply, located on the upper left side of the unit:



  2. Remove the filter case by pushing down the lever and rotating the case in a counterclockwise direction:



  3. Remove the filter cartridges by rotating them in a clockwise direction:



  4. Replace the filter cartridges with the new filter cartridges, supplied in the air pressure unit kit:



    Important: Do not to discard the black bases belonging to the previous white filter cartridge:



  5. Turn the knob counter clockwise to open the air supply, located on the upper left side of the unit.

    This opens the air inlet valve and the air supply flow resumes.

  6. Enter the date that the filter was replaced on the adhesive supplied in the kit. Affix the adhesive to the air pressure unit:



    Important: Check the air pressure gauge to make sure the air pressure is set to 6 psi (90 bar). If required, adjust the air pressure by turning the knob located under the air gauge:



Technical contact(s)
 

Content owner: Itai Peperovich
See the Escalation page for escalation contacts.

Date submitted
 

28 Apr 2005


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.