Machines affected |
All |
|---|
Error number |
- |
|---|
Component |
Drum Vacuum Drive |
|---|
Problem |
Drum Vacuum Drive's Inverter Drive will not respond to manual commands. |
|---|
Symptoms |
The Drum Vacuum Pump enclosure feels very hot on the
surface. |
|---|
Causes and Solutions |
Fault condition disables Inverter DrivePower disconnectedImproper wiringImproper use of the Inverter Drive
WARNING! · Working with the DVD when the cover is off is extremely hazardous due to the presence of high voltages.· The Inverter Drive retains the high voltage power for at least 5 minutes after power down.
Fault condition disables Inverter Drive If the alphanumeric display indicates a fault is present, refer to Drum Vacuum Drive Fault Detected document. If Inverter Drive's alphanumeric display is blank, power may not be present.
Improper wiringRemove the DVP cover..
Improper use of the Inverter DriveIf the Inverter Drive appears to be functional but the Vacuum Pump is not functional, operation of the Inverter Drive is incorrect.
|
|---|
See also |
Drum Vacuum Drive fault detected |
|---|
Technical contact |
Ted Nivolianitis |
|---|
Date submitted |
24 December, 1999 |
|---|
Date modified |