Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
Applies to |
ThermoFlex |
|---|
Machines affected |
All |
|---|
Error number |
DVC13: Drum Vacuum regulation lost, pressure too high. DVC14: Drum Vacuum regulation lost, pressure too low. |
|---|
Component |
Drum Vacuum System |
|---|
Problem |
Drum Vacuum System cannot regulate pressure and shuts off. |
|---|
Symptoms |
Drum Vacuum System shuts down during operation. |
|---|
Causes and Solutions |
Vacuum disconnects from the systemIf a vacuum tube disconnects from the system, the pressure in the drum rises to atmospheric pressure.
Cables disconnected
Vacuum pressure sensor has disconnected
Gain parameter set incorrectly
|
|---|
See also |
n/a |
|---|
Technical contact |
Ted Nivolianitis |
|---|
Date submitted |
23 December, 1999 |
|---|
Date modified |
14 February, 2000 |
|---|