Replacing the registration bar
The following procedure applies to both cross-punch and customized solutions.
- In the ThermoFlex Controller software, open the top door.
- Open the unloading tray.
- Remove the four hex screws on the right registration bar.
- Insert two long hex screws into two of the hex screw holes and then
use the screws to lift out the registration bar.

- Insert the new registration bar.
- Insert and tighten the four screws that you removed in step 3.
- Repeat steps 3 to 6 on the left registration bar.
Installing the registration pin holder
- Open the platesetter's right door.
- Holding the registration pin holder as shown, insert and tighten the
two screws.
- Thread the two connectors through the hole in the mainframe bracket,
as shown in the photograph above.
- Disconnect the interlock connector from the interlock Molex®
connector (shown in the photograph in step 6).
- Attach the registration pin holder connector to the interlock Molex
connector.
- Attach the interlock connector to the registration pin holder Molex
connector.

|