Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
Description | Fixes and Features | Install Time and Order | Dependencies | Workflow Compatibility
CD: 651-00017B-A (link points to CD files on Production's master server). Order the CD from CD.Requests@Creo.com.
| Component | Version | Release Notes |
|---|---|---|
| Print Console | 3.4.2 | Release Notes |
| Service Shell | 2.4 SP1 | Release Notes |
| MCE firmware | 1.12.16 Main Master 1.04.06 Slave |
Release Notes |
| Xilinx/LCA/FPGA,MCE firmware | 1.65 | |
| MCE Post firmware | 1.05 | Release Notes |
| PDB/Genine/Lionel/MCE Recovery firmware | 1.00 | Release Notes |
| PDB/Genine/MCE Boot firmware | 1.09 | Release Notes |
| Lionel Boot firmware | 1.00 | Release Notes |
| PDB/Genine/Lionel Main firmware | 1.17 | Release Notes |
| PDB/Genine/MCE BMM firmware | 1.09 | Release Notes |
| Genine SNIF firmware | 1.03 | Release Notes |
| Thermal Head 1.7 firmware | 1.83 | Release Notes |
| TH2 firmware | 1.02 | |
| Version config file | TS NEWS MCE.ini TS NEWS 200 MCE.ini |
SAP part number for kit that includes CD plus Print Console 3.2 Quick Start Guide: 634-00010A-C.
For general information about controlled releases, see the FAQ for Controlled Releases.
See the release notes for each component for more information.
Install in the order given. Total time - 2 hours (minimum).
Before you begin, review the Dependencies and the readme.txt file in the CR2.0 folder.
| Task | Time |
|---|---|
| If device has UDRC, make sure that the UDRC vacuum connection is to the U67 sensor on the MCE board (see page 3 of Assembly Drawing). The U67 sensor is located at upper left corner of the MCE board with blue tubing attached. If the blue tubing is not attached to the U67 sensor on the MCE board, you may have to disconnect the tubing from the 10-4581A sensor board under the carriage drive board and connect it to the U67 sensor on the MCE board. | 10 minutes |
Install or upgrade Service Shell - needed for
checking head/mce f/w versions and for downloading the new f/w.
|
5 minutes |
| To upgrade firmware; backup parameters; download new MCE firmware; check parameters | 1 hour |
| Upgrade Print Console | 5 minutes |
| Check that device and all applications are functional including load/unload of small/medium/large size media | 15 minutes |
| Demo and provide instructions on changes to customers | 15 minutes |
Workflow items are not part of the release, but have been tested for compatibility.