Trendsetter
MPE Controlled Release Version 1.2 (ECO CA00778, May 2003)

Description | Fixes and Features | Install Time and Order | Dependencies | Workflow Compatibility

Description

Controlled release that includes MPE firmware to support small plates and fourth pin on devices with 4 pin drum.

CD: 21-0139C (link to content of the CD on the master server)
Order this CD from CD.Requests@Creo.com.

Component

Version

Release Notes

Print Console 2.1.1.24 Release Notes
Service Shell 2.4 SP1 Release Notes
Trendsetter MPE Firmware

B version (TEE)

2.53 Release Notes
Trendsetter MPE Firmware

A version (TIF)

2.51 Release Notes
TEH 1.7 firmware 1.83 Release Notes
Version config file
TS 400-800-MPE.INI
1.2  

SAP part number for kit that includes CD plus Print Console 2.1 Quick Start Guide: 20-0192C

For general information about controlled releases, see the FAQ for Controlled Releases.

Major features

This controlled release includes:

New features in MPE Firmware 2.53b:

New features in Service Shell 2.4 SP1:

See the release notes for each component for more information on fixes and features.

Time and Order to install and/or upgrade from previous release

Install in the order given. Total time - 3.75 hours (minimum).
For more information see the release notes for each component.

Task Time
Service Shell installation - needed for checking head/mpe f/w versions and for downloading the new f/w.
After installing the SS client, start the version checker applet. Click Config. A dialog box prompts you for the controlled release config file. Browse to the VersionConfig folder on the controlled release CD, select the version config file, and click Evaluate > Yes.
If a dialog box indicates that the device is not yet configured with controlled release version information, select Configure System > Next. Browse to the VersionConfig folder on the controlled release CD, select the version config file, and click Finish.
For more info on SS, see the SS website.
0.1 hour
To upgrade firmware, including checking head and MPE f/w versions; backup NVS parameters - fsave all; nvs dump; download new mpe f/w; nvs upgrade; checking nvs parameters 1 hour
Check that device and all applications are functional including load/unload of small/medium/large size media 1.5 hours
Demo and provide instructions about changes to customers 1 hour

Dependencies

MPE “E” version required (10-3692A).

Workflow Compatibility

Workflow items are not part of the release, but have been tested for compatibility.