Symptoms |
Picker guide wire and/or pulleys wear excessively |
|
|
|
||
Cause |
The angle that the cable (non adjustable ends) is tightened down at is critical. The cable, on both sides of the picker, needs to be angled back towards the pulley at the bottom of the rail. Otherwise when the picker is in the down position ,it torques the cable back causing fraying of the wire and gives a false reading of the tension in the down position. Note: check for ECO 042 to replace the current part with a shoulder bolt so the position of the guide wire is self-correcting. |
|
|
|
||
Solution |
|
|
|
|
||
Technical contact(s) |
||
Submitted by |
||
Date submitted |
16 Jan 2001 |
|