Description |
Error message issued |
Causes |
Main Drum Drive Amplifier: 3244, VLF Fault signals are asserted from within the drive amp when pin 7on J2 is below 0.8V. This signal is latched, but the exact cause of the failure within the amp is difficult to determine. The green status led next to J2 on the drive amp is lit unless there is a servo amp fault.
|
Solutions |
Clear drive amp faults by turning machine power off and then
on again. If a fault persists, it will "relatch" on after machine reboot.Fault issued on power up or resetEnter a drum init command. Amplifier hot to the touchNormal operating temperature of the heatsink is 55° C = 131° F Replace amplifier. Hall faultsDrive amp Hall LED test in General VLF drum drive, encoder, and PLL
troubleshooting. |