Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS



Drum does not move at all (error number 6026)


Applies to

  • VLF Platesetter
  • VLF Trendsetter
  • ThermoFlex
  • Platesetter 3244
  • Trendsetter 3244
  • Trendsetter 3230 (TS4 version)
  • Renaissance I Scanner

Description

The message "Time out waiting for TPU hall sensor PWM" displays. Drum amp LEDs appear normal, but the drum does not move at all when you type the command drum init.

Causes and solutions

For the VLF Platesetter, VLF Trendsetter, and ThermoFlex:  Fuse F4 on the Power Distribution Board (10A) has blown and must be replaced.

For the Platesetter 3244, Trendsetter 3244, Trendsetter 3230 (TS4 version), Renaissance I Scanner: Fuse F15 on the Power Distribution Board (8A) has blown and must be replaced.

Note: There are separate fuses on the PDB for logic power and motor power.

See also

DRUM: Timeout waiting for TPU hall sensor PWM measurement (error number 6026)
CTP firmware error message 6026