A:  Safety and Exterior

Objectives:  Check safety first!  Determine that all TS VLF components are safe to operate and to work on. Walk around the entire device to examine the exterior and surroundings for damage and any issues that may require further investigation or repair.
Time needed:  10 minutes  (Device can be returned to customer any time.)

Safety and Exterior Evaluation What to Do What to Look For Procedure

Parts

Right e-stop switch Depress the switch. Check that the workstation message is correct.  
Panel interlocks Open each panel. Ensure that the safety interlocks are operating correctly. Isolating the faulty door sensor
Chiller fluid leaks Check floor at the side of the TS VLF and chiller. Ensure that there are no external fluid leaks.  
Debris cabinet hose Check exterior hose. Ensure that it is not being crushed or broken.  
Panels, skins, and table Visually inspect the overall condition of all surfaces.    

B:  System Operation

Objectives:  Determine that the Trendsetter VLF is operating correctly. Watch and listen. Note irregularities for further investigation.
Time needed:  20 minutes  (Device can be returned to customer any time.)

System Operation What to Do What to Look For Procedure

Parts

Operator feedback Speak with the operators and prepress manager.    
Operator training Make sure the operators understand how to operate the device safely.    
Backup settings #1 Backup the following info:
  1. list version
  2. list stats
  3. laser
  4. mask
  5. head mask
  6. set drum
  7. set carriage wsearch
  8. set mode 1 edge
  9. ale
  10. set sys
  11. list plate
  12. nvs dump diff
  13. fsave all
  1. Compare to latest controlled release
  2. # of resets, 'on' time, images, and retraces
  3. 'laser on' time
  4. Is anything masked?
  5. Is anything masked?
  6. chkfly enabled?
  7.  
  8.  
  9. Static pressure
  10.  
  11.  
  12.  
  13.  
 
**Submit a test plot.**
P-door Watch and listen. Smooth, symmetrical and quiet movement.  
Table vacuum ports Watch and listen. Holds plate, without slipping, during the load and unload.  
Table movement Watch and listen. Smooth, symmetrical and quiet movement.  
Electronic registration Watch green light and listen.; Quick and solid registration.  
Plate loading onto drum Watch and listen.    
Edge detection Listen and watch monitor. Finds edge quickly, on first try.  
Carriage operation Listen. Listen for any irregular noises.  
Plot operation Listen and watch monitor. Listen for retraces and any irregular noises.  
Plate unload from drum Watch and listen.    

C:  Imaging

Note:  To properly assess image quality, the processor should have been serviced and filled with fresh chemistry within the last 24 to 48 hours.

Time needed:  2 hours, 15 minutes  (Device can be returned to customer within 25 minutes.)
For this procedure you will need:

For full details, refer to Thermal 1.x Exposure Head Preventative Maintenance 

Imaging What to Do What to Look For Procedure

Parts

NVS settings Back-up NVS. In Splot or ServiceShell, run: savecfg.spt    
Reference plot Run the standard test plot agreed to by the customer.

Examine customer's image reference plot. Agree on a test plot that fits with what LPI and quality of jobs the customer is doing (FM/AM Proofing, linework, or high quality).

 
Reference stroke cal Create a Stroke cal reference. In Splot or ServiceShell, run: strokcal.spt.

Wait for the graph to appear.

Examine the strokecal.spt graph in ServiceShell. This will give a baseline as to the health of the head. Compare to the factory or previous graphs and keep for reference.

Refer to the sample graphs at the end of the Thermal 1.x Exposure Head Preventative Maintenance .

Laser power Check the laser power.
  1. Type:
    >>mode media
    x(x=media in use)
    >>laser on
    >>laser
  2. Record the current value that the head draws at the specified wpower. Record laser on time in hours.
    Type:
    >>set head nomlsrcur
  3. The current should be less than nomlsrcur. Type:
    >>head power sum (use >>head power full if firmware version is earlier than 1.62v)
    >>laser off

Check the laser output of the head at the wpower for the media that is used. Note and record the current draw when the laser is on.

If the laser current approaching the >>set head nomlsrcur value, it is a good indication the head is nearing end of life.

Check the power at the nosepiece and compare to the power on the Media spreadsheet for the given media.

CTP Media Imaging Performance Database
Sum and focus error Check the sum and focus error. Load a plate on the drum. Type
>>head install on

Check that the sum value is around 1000 units and the error is near 0 (see note, below). A sum lower than 1000 can indicate debris buildup on the final lens. If the lens is clean and the error is not 0 ± 25 units, reinstall the head as per the head install document.
Note: The error may be different on a Spectrum device.

 
  Remove the head

Device must be powered down. All laser safety procedures must be followed.

TH1.0: Thermal 1.0 Head Installation Procedure

TH1.7: Thermal 1.7 Head Installation Procedure

Safety Warning: Follow Laser Safety Procedures during the next step.
Debris removal nozzle Clean the debris removal nozzle using the correct procedure.
See: Importance of lens cleaning and debris removal

The pressure tap in the vacuum nozzle needs to be clean of debris in order for the debris removal system to work properly.

TH1.7 Debris Removal Nozzle Cleaning Procedure
Lens Clean the lens using the correct procedure.
See: Importance of lens cleaning and debris removal
Leaving streaks can seriously impact imaging quality.

TH1/1.7 Lens Cleaning Procedure (77-0125A)

Note: make sure you order the lens cleaning kit (Lens cleaning kit: 04-0012B BOM).

  Install the head

Follow the head installation procedure.

  • Check that the sum value is around 1000 units and the error is near 0
  • If the lens is clean and the sum is lower than 1000, you may need to adjust the surface reflectivity

TH1.0: Thermal 1.0 Head Installation Procedure

TH1.7: Thermal 1.7 Head Installation Procedure

New stroke cal Generate a new stroke cal. In Splot or ServiceShell, run: strokcal.spt
Wait for the graph to appear.

Generate a new stroke graph and compare it to the stroke reference graph (Step 3) to determine any changes as a result of the nozzle or lens cleaning.

Refer to the sample graphs at the end of the Thermal 1.x Exposure Head Preventative Maintenance .
  Compare stroke graphs. Type >>set head Bpmaxerr xxx

Compare the strokecal graph obtained in the previous step to the sample graphs (at the end of the Thermal Head 1.x Planned Maintenance) and determine if any parameter adjustments are necessary.

Thermal 1.x Exposure Head Preventative Maintenance 
Contrast script Run the contrast script.

In Splot or Service Shell run: getcontr.spt

If adjustments are required, type:
>>set head Bposn xxx

Compare the graph obtained to the sample graphs at the end of the Thermal Head 1.x Planned Maintenance. Determine if any adjustments are necessary.

Note: This may cause a change in the strokecal graph. If changes were made to the Bposn value, repeat Steps 27 to 28.

Thermal 1.x Exposure Head Preventative Maintenance 
Laser power Verify the laser power.
  1. Type:
    >>mode media
    x(x=media in use)
    >>laser on
    >>laser
  2. Record the current value that the head draws at the specified wpower. Record laser on time in hours.
    Type:
    >>set head nomlsrcur
  3. The current should be less than nomlsrcur. Type:
    >>head power sum (use >>head power full if firmware version is earlier than 1.62v)
    >>laser off

Verify the laser output of the head at the wpower for the media that is used. Note and record the current draw when the laser is on.

If the laser current approaching the >>set head nomlsrcur value, it is a good indication the head is nearing end of life.

Check the power at the nosepiece and compare to the power on the Media spreadsheet for the given media.

CTP Media Imaging Performance Database
ECOs/FCOs and firmware Check that all ECOs/FCOs have been implemented on the thermal head. To see the current firmware version of the head, type:
>>head or >>list version

A list of FCOs can be seen at the FCOs page of the Thermal 1/1.7x TechPlanet site. Also check that all firmware upgrades have been carried out.

 
Shutter

Test the operation of the lens shutter. Type:
>>shutter open
>>shutter close

Another test option is to type >>focus cal reflect and listen to the shutter rapidly opening and closing.

If possible, listen to the sound and check that operation is normal. Clean the shutter, if necessary.

Thermal 1/1.7 Shutter Sensor Replacement Procedure 
NVS settings Final NVS save. In Splot or ServiceShell, run: saveconfig.spt

Generate a final strokecal graph and a THXXXX.cfg file that can be used for future reference. This script takes approximately 6 minutes to run. Leave the THXXXX.cfg file on the workstation for future reference.

 

 

  What to Do What to Look For Procedure

Parts

Cables to imaging head      
Carriage Allow 15 minutes, 5 minutes to return device to customer    
Carriage rails Lubricate.   Lubricating the Carriage Tracks and Leadscrew
Lubricating the leadscrew hanger bearing
Carriage lead screw Lubricate.  

 

Dehumidifer Unit (DHU) What to Do What to Look For Procedure

Parts

DHU

Each device will have a head-mounted Dehumidifier Unit (DHU).

  1. Power down the device and purge all air from the system.
  2. Replace the filter (PN 55-1219).
  3. Turn the air on and power up the device.

CAUTION: If the differential pressure indicator displays red you need to examine the bowl to determine if the device has been tripped by moisture or oil in the line. You must replace the DHU (part number 05-0244) once it has been tripped, then investigate why the DHU tripped. Rectify air quality before reinstalling the new DHU.

Note: If the device has a desiccant box: upgrade the Desiccant pack to a DHU (kit #05-0244). For details, see the Dehumidifier Unit FCO E246 information.

Dehumidifier Unit (DHU) Installation Procedure
  **If the pressure indicator is red, the DHU MUST be replaced and the air system examined for contaminants.**

**If the Trendsetter VLF still has a desiccant box, upgrade to a DHU (kit #05-0244).**

 

  What to Do What to Look For Procedure

Parts

Debris Removal Unit Allow 15 minutes, 5 minutes to return device to customer    
Check sensor Turn on the debris cabinet. Block the front of the nozzle with cardboard. A warning should appear on the workstation, and the vacuum motor should whine louder.  
Filter Check condition.    
Hose Check that all clamps are secure. Inspect the vacuum hose. Inspect for wear along the hose tray, and for crushing along the floor.  
Chiller Allow 30 minutes, 5 minutes to return device to customer   Neslab/Polyscience External Chiller Planned Maintenance 
Leaks Remove the side panels and visually inspect the internal system for leaks.   Neslab/Polyscience External Chiller Planned Maintenance
Condenser and air vents Remove the front filter element. Wash it with water and mild detergent. Vacuum the grills, vents and condenser. Excessive buildup of dust and debris. Neslab/Polyscience External Chiller Planned Maintenance
Pump strainer/fluid filter Drain off some of the chiller fluid. Remove the sediment bowl or strainer. Clean and re-install the filter.   Neslab/Polyscience External Chiller Planned Maintenance
Pump motor Add 30-35 drops of electric motor oil to each motor bearing.   Neslab/Polyscience External Chiller Planned Maintenance
Fluid Top up the fluid to the correct level.   Neslab/Polyscience External Chiller Planned Maintenance
Image Quality      
Image quality #2 Run another test plot and inspect the results.    

D:  Trendsetter VLF

Objectives:  Check everything, then go back and repair or adjust as required.
Time needed:  2 hours  (Device can be returned to customer within 15 minutes.)

Trendsetter VLF What to Do What to Look For Procedure

Parts

Power Box      
Keyswitch Check operation in both positions. Leave in 'mech hazard' position for the rest of the Trendsetter VLF section of the PM.    
  **If the keyswitch is not installed, order kit #05-0048 (FCO C216).**
MOV Test the MOV on the PDB and replace as required.   10-3562
Cooling fans Check for adequate flow and lack of excessive noise.    
Fan Box      
  **Open the panel.**
Intake air filters Replace filters.    
Compressed air filters Replace filters.    
Air dump Test functionality.    
Air supply pressure Test compressed air supply.    
Air leaks Check for leaks around regulator.    
  **Close the panel.**
Engine      
  **Open the hood.**
Time engine #1      
P-door actuators Check for loose fasteners, leaks and smooth symmetrical operation.    
Drum and LEC Clean and inspect.    
Drum straps Check and tighten all strap fasteners.    
Drum belt Visually inspect the condition and tension of the belt.    
Encoder disk Clean the disk (glass encoder only).    
  **If the disk is excessively dirty, consider doing a shaft encoder upgrade - kit #05-0195 (FCO D992).**
Rollers Clean with a damp, lint-free rag.    
Roller actuators Check for leaks.    
Roller pressure Check pressure to the cylinders. It should be 55-60psi.    
Roller movement Check for smooth, symmetrical movement.    
Roller rotation Should rotate freely by hand with the backbone up.    
TEC actuators Check for leaks.    
TEC pressure Check pressure to the cylinders. It should be ~30psi.    
TEC magnets Clean off any debris.    
TEC rod ends     Trendsetter VLF PM Procedure
TEC lock/unlock     Trendsetter VLF PM Procedure
TEC sensors Visually inspect. If any cable sockets are loose, replace the sensor. 10-1065A
Backbone sensors     Trendsetter VLF PM Procedure
LEC hinge Inspect for wear and dust.    
LEC actuators Check for leaks.    
Backbone actuators Check for leaks.    
  **Remove the side panels.**
Carriage fan Check for dirt and adequate flow.    
Carriage belt Check for wear and tension.    
Main manifold Check for leaks.    
Table vacuum generator Replace the filters.    
Balance weight actuators Check for leaks, looseness, and release tip.    
Balance weight hall sensors     Trendsetter VLF PM Procedure
Balance weights Lubricate the release tips, engagement rings, and balance races.    
Balance weight release alignment     Trendsetter VLF PM Procedure
Balance weight smooth operation     Trendsetter VLF PM Procedure
  **If the balance detent arm or detent spring do not operate smoothly, install kit #05-0233 (FCO E269).**
Time engine     Trendsetter VLF PM Procedure
Table and P-door      
Table slide gate Visually inspect. Check for smooth operation.  
Table condition Inspect the surface. Look for excessive wear and stability of the wings.  
Leading edge Check with a straight edge. Should be flush and flat to the table surface.  
  **Type >>ale init to position the drum. Raise the table.**
Table to LEC distance Check the distance with a ruler at both ends of the drum. It must be parallel.   table alignment procedure
Table tangent to drum Check the distance with a ruler at both ends of the drum.   table alignment procedure
Plate drop Check the plate drop distance. Adjust plate stop only.    
  **Put all Trendsetter VLF panels back on, and close the hood.**

E:  Workstation

Objectives:  Test the system thoroughly before leaving the site!  Update any/all firmware and Print Console. Note updates under Service Commands on the customer's PM Checklist.
Time needed:  2 hours  (Device can be returned to Production within 60 minutes.)

Refer to the Control-Settings page for details of controlled releases.

Workstation What to Do Procedure

Parts

SCSI cable Visually inspect the overall condition of the SCSI cable and connections. Replace as required.  
Service Shell software Update to the current Controlled Release version. current version
Print Console software Update to the current Controlled Release version. current version
Head firmware Update to the current Controlled Release version. current version
MPE firmware Update to the current Controlled Release version. current version
Backup settings #2    
  **Test operation.**

F:  Service Comments

Complete the "Service Comments" section of the Trendsetter VLF Planned Maintenance Checklist 725-00013A. For the customer's information, make a note of:

G:  Customer Acceptance

To complete the PM, the Planned Maintenance Checklist 725-00013A must be signed off by the customer and returned to Creo.


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.