| FCO | Description | Release Date | Priority | Service Actions |
|---|---|---|---|---|
| D646 | Shutter Replacement | August 2000 | Next shutter failure | Replace the shutters according to the following procedure:Thermal 1/1.7 Shutter Sensor Replacement Procedure |
| E445 | Improved debris nozzle(50-2117C) is less likely to clog the vacuum sensor port with ablative debris. Click on the photo below for old and new versions of nozzle.![]() |
Jan 2002 | Next failure | Order kit 05-0246 - includes nozzle,air jet plate, tube and fitting Install procedure |
| E453 | DHU Kit updated: valve added, kit part numbers updated. | 22 Oct 2001 | Next Failure | Refer to the Dehumidifier Unit (DHU) Installation Procedure. Be sure to order the correct kit. Note that the part numbers have changed: |
| E246 | Replace desiccant box with dehumidifier unit | Aug 2001 | Next Failure | Discontinue desiccant systems. Replace with dehumidifier systems that provide clean dry air to slightly pressurize (0.05 tp 0.5" WG) the optical cavity. Refer to the Dehumidifier Unit (DHU) Installation Procedure. |
| CA13653 | Remove the cable connector cover (PN 57-5934A) | Nov 2007 | Next Visit | Remove the cable cover from the head. See the procedure in FCO CA13653. |
| D404 | New airjet plate without window | April 2000 | Next Visit | Upgrade
ALL 1.7X heads on V-machines with new airjet plate (kit PN
30-1163A-C) Air Jet Plate Assembly Installation Procedure |
FCO CA12621: New yellow Propylene Glycol coolant(090-00326A) replaces pink Ethylene Glycol coolant(82-1032A). For details, see the Trendsetter FCOs page.
For all obsolete FCOs, see Thermal 1/1.7 FCOs Archive.