Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
| Applies to |
|
|---|
| Machines affected | All machines. |
|---|
| Error Number | None |
|---|
| Component | Table |
|---|
| Problem | The table moves up while the y-axis is still extended because the firmware reads that the y-axis is at home. |
|---|
| Causes and Solutions | Cause 1:
Home sensor is damaged.
Solution: Replace the sensor. See VLF Trendsetter AL Sensors and Switches. Cause 2: Sensor cables are damaged.
Cause 3: Genine0 board has failed.
|
|---|
| Technical contact | Dal Wagner |
|---|---|
| Date submitted | 18 May 2000 |
| Date modified |