Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Table moves up with y-axis still extended

Applies to
  • VLF Trendsetter AL

Machines affected All machines.

Error Number None

Component Table

Problem The table moves up while the y-axis is still extended because the firmware reads that the y-axis is at home.

Causes and Solutions Cause 1:  Home sensor is damaged.
Solution: 
Replace the sensor. See VLF Trendsetter AL Sensors and Switches.

Cause 2:  Sensor cables are damaged.
Solution:
  Replace the damaged cable.

Cause 3:  Genine0 board has failed.
Solution:
 Replace the board. For more information, see VLF Trendsetter AL Genine boards.


Technical contact Dal Wagner
Date submitted 18 May 2000
Date modified

    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.