Problem The table does not move up or down.

Causes and Solutions Cause:  The conveyor interface plate is not attached properly.
Solution: 
The conveyor interface plate must be completely snapped down so that it makes contact with the two sensors underneath. One sensor is connected to the safety loop of the base machine; the other is part of the VLF Trendsetter AL safety loop. For more information see the safety loop wiring diagram:  Safety circuit, 73-3657


Technical contact Dal Wagner