Component
|
|
Carriage drive board (48V DC)
Part#'s 10-3761, 10-4935, 503C01525, and 10-4975.
Note: On Trendsetter 800, does not apply
to older style carriage drive board 10-1418C. On Trendsetter VLF AL, only
applies to picker and L-conveyor carriages. Does not apply to carriage
drive board 10-1312C used on the Trendsetter VLF base machine.
|
Solution
|
|
If you see any of the symptoms listed above, or you observe other
strange carriage-related behaviour, please follow these steps before
replacing the drive board or motor:
- Set the carriage/picker in motion. Only a very slow speed is needed
for these tests.
- For MPE based Trendsetters, type
carriage move 50
- For Lotem devices and MCE based Trendsetters, type
carriage
move 3
- For Trendsetter VLF AL, type
picker move 3000 10
- Set a voltmeter to measure DC Voltage.
- For 10-3761, 10-4935, and 10-4975:
Using the voltmeter, measure the DC voltage between ground and
board test points TP5, TP9, TP15 and TP17.
Ideally, these should all measure 0V to ground, which would
indicate zero DC offset. Any reading greater than 150mV for any
of the test points is excessive and the board should be replaced.
Service stock has been reworked, so the replacement board should not
have the faulty capacitors.
It is very important that the carriage is in motion during
this test. If the motor is not spinning, then any of the testpoints
could have valid signals up to 5V.
- For 503C01525:
Using the voltmeter, measure the DC voltage between ground and
board header pins J4-1, J4-2, J4-6 and J4-7.
Ideally, these should all measure 0V to ground, which would
indicate zero DC offset. Any reading greater than 150mV for any
of the test points is excessive and the board should be replaced.
Service stock has been reworked, so the replacement board should not
have the faulty capacitors.
It is very important that the carriage is in motion during
this test. If the motor is not spinning, then any of the testpoints
could have valid signals up to 5V.
- Idle the carriage or return the picker.
- For Trendsetter 800, type
carriage idle
- For Lotem devices and MCE based Trendsetters, type
carriage
idle
- For Trendsetter VLF AL, type
picker init
Note about Trendsetter NEWS: There have also been
carriage problems with Trendsetter NEWS machines, exhibiting similar
symptoms. The cause can be different, however.
Some newspaper devices that use a Thermal II head have too few head
flex track links. The head will stall due to the flex track not having
enough travel at one end of the carriage. All Trendsetter NEWS and
Trendsetter 800 machines using the Thermal II head must have 19 links in
the head flex track (18-3345), not including the mounting links at each
end.
|