Cause 1: Y-axis does not
extend/retract properly
Solution: See Y-axis does not extend/retract to
correct position.
Cause 2: Gripper has failed mechanically.
Solution: Check the gripper:
- Type 'gripper on'
- Place a plate on the table
- Type 'gripper clamp on'.
- Pull gently on the plate
If the gripper fingers don't hold the plate, the leaf springs or the air cylinder may have failed. Replace the whole y-axis assembly.
Cause 3: Genine 0 board has failed
Solution: See VLF Trendsetter AL
Genine boards.
Cause 4: Faulty connections
Solution: Check for poor connections or faulty wiring between the valve and
Genine 0 board. |