Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
| Applies to |
|
|---|
| Machines affected | All machines that have a Single Cassette Module installed. |
|---|
| Error Number | None |
|---|
| Component | Docking station |
|---|
| Problem | The air cylinder on the docking station won't move properly. |
|---|
| Causes and Solutions | Cause 1: Travel is out of
adjustment. Solution: Adjust the collar on the cylinder, moving it towards the end of the rod and away from the cylinder. Cause 2: Cylinder has failed mechanically. Cause 3: Cylinder air supply inadequate |
|---|
| Technical contact | Gordon Andrew |
|---|---|
| Date submitted | 28 March 2000 |
| Date modified |