Symptoms |
Hot folder conflicts exist between CS Xpose 1.00.76 and 1.01 and Prinergy 2.1. When starting up Prinergy software, the Hotfolder daemon crashed error message appears, but Prinergy continues to start. In Prinergy Workshop, if you try to use the hot folders you will get an error message unexpected Corba error and the Prinergy Workshop no longer responds. You can no longer use hot folders in Prinergy. |
||
Solution |
Read the Pringery 2.1 patch 7 Readme.txt and upgrade Prinergy 2.1 to the Prinergy 2.1 patch 7 to resolve the hot folder conflict. |
||
See also |
Once you have installed the Prinergy 2.1 patch 7, it is recommended that you read the Prinergy 2.1 patch 8 Readme.txt and install the Prinergy 2.1 patch 8. |
||