Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Hot folder conflicts exist between Prinergy 2.1 and CS Xpose


Product

 
  • CS Xpose 1.x
  • Prinergy® 2.1

Platform

 

Dell® 2500H, 2500V and 6400 workstations

Operating system

 

Windows® 2000 Server


Symptoms

 

Hot folder conflicts exist between CS Xpose 1.00.76 and 1.01 and Prinergy 2.1.

When starting up Prinergy software, the “Hotfolder daemon” crashed error message appears, but Prinergy continues to start. In Prinergy Workshop, if you try to use the hot folders you will get an error message “unexpected Corba error” and the Prinergy Workshop no longer responds. You can no longer use hot folders in Prinergy.


Solution

 

Read the Pringery 2.1 patch 7 Readme.txt and upgrade Prinergy 2.1 to the Prinergy 2.1 patch 7 to resolve the hot folder conflict.


See also

Once you have installed the Prinergy 2.1 patch 7, it is recommended that you read the Prinergy 2.1 patch 8 Readme.txt and install the Prinergy 2.1 patch 8.


Technical contact(s)
 

David Weill

Submitted by
 

DJ Dunkerley

Date submitted
 

12 Nov 2002


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.