Symptoms |
Prinergy does not appear in Print Console's list of available RIPs, which means Prinergy is not connected to Print Console. |
||
|
|
|||
Cause |
This is a Prinergy problem that only happens if you uninstall the Prinergy 2.0.5 update patch and revert to version 2.0.4. When uninstalling the v2.0.5 patch, the uninstaller resets the path to the original v2.0.4 path variable. If new items were added to the system path variable since the v2.0.5 patch was installed, they are lost when the uninstall program reverts to the 2.0.4 path. In other words, if you installed a program such as Print Console after upgrading to v2.0.5, the associated path items are lost when you revert to v2.0.4. |
||
|
|
|||
Solution |
Add the necessary Print Console entries to the System Variable Path:
|
||
|
|
|||
See also |
Same problem described from a Prinergy perspective. | ||
|
|
|||
Technical contact(s) |
|||