Migration tool fails to convert Print Console 3.8 data to 4.6 data


Product

  Kodak® Print Console software, upgrade from version 3.8 to version 4.6 (Magnus VLF controlled release 4.0)

Machines affected

 

Magnus VLF with the MCU option


Symptoms

 

While using the Print Console Migration Importer tool to convert Print Console 3.8 settings to Print Console 4.6 settings, the Importer tool reports that it cannot find the cassette configurations.


Cause

 

The migration tool, which is included in the controlled release, has:

  • An exporter tool, which collects Print Console 3.8 data and stores it in an XML file
  • A Print Console importer tool, which finds media sizes, device media settings, cassette configurations, and relevant preference settings in the XML file and imports them into Print Console 4.6
The problem occurs because the 3.8 data in the XML file contains a value named Cassette, but the Print Console importer tool is looking for a value named CassetteId.


Solution

 

The solution is to change the data in the XML file from Cassette to CassetteId. See Migration Tool Fails to Convert 3.8 Data to 4.6 Data for the procedure.


Technical contact(s)
 

Jose Delgado

Submitted by
 

Hugo Noel

Date submitted
 

25 May 2007