Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
Product |
Kodak® Print Console software, upgrade from version 3.8 to version 4.6 (Magnus VLF controlled release 4.0) | ||
Machines affected |
Magnus VLF with the MCU option |
||
Symptoms |
While using the Print Console Migration Importer tool to convert Print Console 3.8 settings to Print Console 4.6 settings, the Importer tool reports that it cannot find the cassette configurations. |
||
Cause |
The migration tool, which is included in the controlled release, has:
|
||
Solution |
The solution is to change the data in the XML file from Cassette to CassetteId. See Migration Tool Fails to Convert 3.8 Data to 4.6 Data for the procedure. |
||
Technical contact(s) |
|||
Submitted by |
|||
Date submitted |
25 May 2007 |
||