Machines affected |
All machines with Firmware 0 or Firmware 1 or Lotem Control Software |
||
Component |
UDRC (B Configuration), POC Monitor |
||
Error |
27014/43014: The debris hose is disconnected, the cabinet has lost power, or the cabinet lid is not latched properly |
||
Symptoms |
|
||
Cause |
The debris collection hose is disconnected or has a hole, or the cabinet has lost power, or the particulate filter (or filter spacer) is installed upside down or is not present, or the lid is not closed, or the spring on the filter detect plunger switch is missing, or the filter detect plunger switch is malfunctioning, or the collection nozzle sensing line may be disconnected, or the nozzle sensing line may be hooked up to the wrong sensor on the TEE board (particulate-only system (POC)), or the sensing port may be plugged with debris. |
||
Solution |
Cause 1: The debris collection hose is disconnected or has a hole.
Cause 3: The particulate filter (or filter spacer) is installed upside down or is not present. Solution:
Cause 4: The lid is not closed. Solution: Ensure that the lid closes securely, without using excessive force. Cause 5: The spring on the filter detect plunger switch is missing. Solution: Replace the spring (part #59-3845). Cause 6: The filter detect plunger switch is malfunctioning. Solution: Test the cabling and/or replace the cables (part #10-4939) and filter detect switch (part #15-3431). Cause 7: The collection nozzle sensing line may be disconnected. Solution: Make sure that the sensing line is connected securely at both ends, between the nozzle and sensor (both are inside the device). Reset the output device to continue. Cause 8: On a particulate only system (POC), the nozzle sensing line may be hooked up to the wrong sensor on the TEE board. Solution: See the upgrade procedure for the Trendsetter 3244/3230 (Doc #73-3639A). Reset the output device to continue. Cause 9: The sensing port may be plugged with debris. When the port is plugged, the sensor stays under vacuum while the system recalibrates, which generates an incorrect offset making the nozzle flow seem low. Solution: Remove the collection nozzle and clean it, making sure to clear debris from the small pressure sensing hole (blow air through it). |
||
See also |
|||
Technical contact(s) |
|||
Submitted by |
|||
Date submitted |
30 Sep 2003 |
||