Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
Product |
UDRC |
||
Machines affected |
All machines with Firmware 0 or Firmware 1 or Lotem Control Software |
||
Component |
UDRC, blower motor |
||
Error |
27014/43014: The debris hose is disconnected, the cabinet has lost power, or the cabinet lid is not latched properly |
||
Symptoms |
The UDRC shuts down several seconds after the output device turns on the blower. The green light on top of the UDRC stays on. |
||
Cause |
Some blower motors do not tolerate the maximum rated voltage well. If the supply voltage is 240VAC, these motors may fail. |
||
Solution |
If the blower motor has failed:
|
||
See also |
|||
Technical contact(s) |
|||
Submitted by |
|||
Date submitted |
07 Nov 2003 |
||