A Field Change Order (FCO) contains only the information from an ECO that relates to service. It lists the problem, its solution(s), what products and components are affected, the service priority, any procedures that need to be done in the field, parts and tools needed, and the date of release.
| FCO | Date Posted | Description | Service Actions | 100 Label # | Priority |
|---|---|---|---|---|---|
| CA06163 | Mar 2005 | New UDRC blower to replace old blower (15-3252) that burned out too fast. | Kit 512-00252A includes cable (220-01041A) and new blower (376-00040) | 5 | Next failure |
| CA00626 | Dec 2003 | UDRC sound reduction | Kit 512-00048B BOM
UDRC Sound Reduction Upgrade Procedure Effective Nov 2005, foam for this kit is not pre-cut. For cutting instructions, see Foam cutting procedure. |
4 | Next failure |
| E445 | Jan 2002 | Improved debris nozzle(50-2117C) is less likely to clog the vacuum sensor port with ablative debris. Click on the photo below for old and new versions of nozzle.![]() |
Kit 50-2113C - includes nozzle and air jet plate Install procedure |
Next failure |
| FCO | Date Posted | Description | Service Actions | 100 Label # | Priority |
|---|---|---|---|---|---|
| CA01187 | Aug 2003 | Strain relief for power cord. | Check the strain relief on the power cord. If the strain relief is fully tightened but the power cord can still be pulled out, replace the strain relief with new part #16-3687. If there are no strain relief components on the power socket at all, install part #16-3687. | Next PM |