Tfx Command
foc actmode [<actuator mode>]

Variables actuator mode Specifies the auto-focus system actuator mode.

Description This command sets the actuator mode of the auto-focus system. The following are valid actuator modes:

Actuator Mode 0 ('current' mode): In actuator mode 0 the input to the actuator is considered to be the electrical current flowing into the coil.

Actuator Mode 1 ('force' mode): In actuator mode 1 the input to the actuator is considered to be the force exerted by the magnetic coil.

Related Documents PARAMETER: foc fca1
PARAMETER: foc fca2
PARAMETER: foc fca3
PARAMETER: foc fca4
PARAMETER: foc fck1
PARAMETER: foc fck2
PARAMETER: foc fcki
PARAMETER: foc actmode

Firmware Notes Actuator mode 0 is the normal operating mode which has been used since the beginning of TH2. Actuator mode 1 was developed to increase the servo performance.

Applies to: TFX THERMAL2
Access: FIELD
Modified: Thu Aug 30 16:23:11 2007
Updated: Thu Jul 17 02:31:30 2008
Module: FOC