Tfx Command
(requires ENG access)
vpc point <velocity>

Variables velocity Surface velocity point to correlate power to (m/s).

Description Determines the power point on the velocity power curve for the specified surface velocity. Uses the current media index. A valid velocity power curve must be specified for the current media index.

Notes The surface velocity must be greater than or equal to the minimum velocity point on the curve. The surface velocity must be greater than 1.5 m/s, and less than 14 m/s.

Related Documents COMMAND: vpc velocity <media> [<velocity_points>]
COMMAND: vpc power <media> [<power_points>]
ERRORCODE: [05300] Invalid function parameter
ERRORCODE: [05301] Velocity curve not initialized
ERRORCODE: [05302] Velocity curve is invalid
ERRORCODE: [05303] Calculated surface velocity is too low
PARAMETER: vpc <media> velocity_points
PARAMETER: vpc <media> power_points

Applies to: TFX
Access: ENG
Modified: Thu Oct 10 11:47:50 2002
Updated: Thu Jul 17 02:31:30 2008
Module: VPC