[01108] The primary parameter section is corrupt

Service Information The registry consists of two 64 byte blocks of EEPROM used as primary and secondary parameter sections. The two sections provide a redundant backup for reading and writing registry keys ( or parameters ).

The status of the primary and secondary parameter sections is determined automatically during initialization and by the monitor command eeprom verify. If an error is detected in the primary parameter section, the firmware will attempt to automatically recover using the secondary parameter section. This error indicates that recovery was not possible typically due to an EEPROM problem.

Operator Action Call service.

Causes
  • Corruption in the primary parameter section typically due to an EEPROM problem.
  • Number of EEPROM write cycles exceeded.

Related Documents COMMAND: eeprom verify
ERRORCODE: [01106] Both parameter sections are corrupt
ERRORCODE: [01107] The primary parameter section was recovered
ERRORCODE: [01109] The secondary parameter section was recovered
ERRORCODE: [01110] The secondary parameter section is corrupt

Applies to: TFX THERMAL2
Modified: Tue Aug 14 12:14:35 2001
Updated: Thu Jul 17 02:31:28 2008
Module: EED