Tfx Errorcode
[01109] The secondary parameter section was recovered

Service Information The registry consists of two 64 byte blocks of EEPROM used as primary and secondary parameter sections. The two sections provide a redundant backup for reading and writing registry keys ( or parameters ).

The status of the primary and secondary parameter sections is determined automatically during initialization and by the monitor command eeprom verify. If an error is detected in the secondary parameter section, the firmware will attempt to automatically recover using the primary parameter section. This error indicates that recovery was possible.

Operator Action Call service.

Causes
  • Corruption in the secondary parameter section due to an interruption during the write of a registry key.
  • Corruption in the secondary parameter section due to an EEPROM problem.

Related Documents COMMAND: eeprom verify
ERRORCODE: [01106] Both parameter sections are corrupt
ERRORCODE: [01107] The primary parameter section was recovered
ERRORCODE: [01108] The primary parameter section is corrupt
ERRORCODE: [01110] The secondary parameter section is corrupt

Applies to: TFX THERMAL2
Modified: Tue Aug 14 12:14:35 2001
Updated: Thu Jul 17 02:31:29 2008
Module: EED