Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


TFX Head News Archive

Product Support News Archive Expand/collapse all news items


TechPlanet DVD Version 5 N.3—01 Nov 2006

23 Oct 2006: Updated EHR Form More...

The Exposure Head Request form (EHR) has been updated. Please delete any locally-stored copies.

See the Exposure head request (EHR) form.

14 Sep 2006: Change in color of optical glass in TFX head front window More...

The color of the optical glass in the TFX Head Front Window (30-1170A ASSY,OPT,FRONT WINDOW,TFX) has changed from blue to orange due to a change in vendor. The functionality has not changed. This information is posted on the TFX Parts/Tools page.

TechPlanet DVD Version 5 N.2—01 Jun 2006

11 May 2006: TFX head firmware version 1.33 released More...

Always download head firmware as part of a controlled release. Note that version 1.33 has only been tested on Wide II devices.

This release features new warning messages when you access stroke tables. For full details see the release notes, available on the Firmware release page.

08 May 2006: Updated EHR form and procedure for ordering a replacement head More...

The Exposure Head Request form (EHR) has been updated and is now a controlled document. Please delete any locally-stored copies and link to the form on TechPlanet: Exposure head request (EHR) form.

Follow the correct procedure to get authorization and order a head ( Ordering a replacement head ).

See also Thermal head experts authorized for head replacements.

TechPlanet DVD Version 5 N.1 and Mature Products 2006—31 Jan 2006

TechPlanet DVD Version 4 N.3—30 Sep 2005

15 Jun 2005: Hebrew translation of MSDS for pink coolant More...

The Hebrew translation of the Material Safety Data Sheet for pink coolant is posted on the Safety page.

TechPlanet DVD Version 4 N.2—31 May 2005

07 Apr 2005: MSDS for acetone and chiller coolant More...

Material Safety Data Sheets for acetone and chiller coolant have been posted on the TechPlanet Safety page.

TechPlanet DVD Version 4 N.1 and Mature Products 2005—31 Jan 2005

TechPlanet CD Version 3 N.3—30 Sep 2004

01 Sep 2004: Service Shell 2.6 is required for the Thermoflex Wide II platform More...

New specifications on the Thermoflex Wide II device allow repeat sizes smaller than 15 inches. These smaller repeats require updated TFX Service Shell scripts to prevent accidental damage to the head. The necessary script updates are contained in Service Shell 2.6, so all users should upgrade as soon as this version becomes available.

The affected scripts are:

Upgrading Service Shell will automatically update all scripts. Download the latest version of Service Shell.

TechPlanet CD Version 3 N.2—14 Jun 2004

TechPlanet CD Version 3 N.1/—16 Feb 2004

02 Oct 2003: Perfectly Good TFX Heads Returned For Repair More...

During 2002-2003 a total of 16 TFX heads were returned. Five of these heads had failed laser diodes and were repaired. However, eight heads were determined to be working correctly and after extensive testing they were returned to stock. In most cases, no information was submitted with the returned head.

To save time and money in the factory, we need to know what is wrong with a head.

The “No Fault Found” heads are costing Creo money. Shipping costs average US$950. Typical turn around time is about 2 months. During this time the head counts towards inventory and the calculated cost of this inventory is US$1300 per head. Therefore, every time the bag containing a head is opened unnecessaraly, it costs Creo more than US$2000.
TFX heads are very reliable - please do all you can to ensure it really is a defective head before you replace it. The product specialists are available to offer a second opinion if you need one. (Contact info for the specialists is available on TechPlanet or from the Escalation link below).

TechPlanet CD Version 2 N.3/4—15 Sept 2003

02 Jul 2003: Posssible TFX Head Window Defects More...

Risk of defect identified with TFX Optical Window, P/N 30-1170A.
Some of the TFX head windows manufactured in the past year are defective. The nature of the defect means the window will not withstand repeated cleaning, possibly causing image artifacts. The root cause of the problem is a defective anti-reflective coating on the bare window (purchased). There is no way of knowing how many of these defective windows are at customer sites, and unfortunately there is no way to check in the field if a window is defective or not. To date, the problem has only surfaced at one site.

TechPlanet CD Version 2 N.2—28 Apr 2003

TechPlanet CD Version 2 N.1—24 Jan 2003

04 Dec 2002: TFX Firmware V1.14 Released More...

TFX head firmware version 1.14 has been released under ECO CA00030. This is a controlled release of TFX firmware, and must only be installed as part of the Thermoflex controlled release.
This version of firmware supports:

Download controlled release information from the Control/settings page of the ThermoFlex TechPlanet site.

TechPlanet CD Version 1 N.4—26 Oct 2002

11 Oct 2002: TFX Head V-Speed Upgrade Procedure Posted More...

A new procedure has been posted that explains how to upgrade a TFX head to V-Speed. Find it on the Procedures page, or download the TFX Head V-Speed Upgrade Procedure.

10 Sep 2002: DHU Update More...

We would like to thank everyone for their ongoing efforts to convert all Thermal 1.x-equipped devices from Desiccant systems to the DeHumidification Unit (DHU).

For DHU installation refer to the Thermal 1/1.7 installation page. For DHU maintenance information, refer to step 10 in the Thermal 1.x Exposure Head Preventative Maintenance document, available from the Thermal 1/1.7 procedures page.

19 Aug 2002: New ProComm scripts for TFX Head More...

The TFX Head ProComm scripts have been updated for use with MPE firmware 1.40. See the Thermoflex Controlled Release v1.1 for instructions on upgrading to the new firmware. See the Downloads page for the new ProComm scripts.

14 Aug 2002: New Flexo Plate Specifications Spreadsheet Posted More...

Refer to this spreadsheet for drumspeeds, imaging times and head power for qualified media for Thermoflex VLF devices only. The setup information includes drumspeeds and exposure information for both V-speed and F-speed devices for a given media type. Download it from the Media homepage.

TechPlanet CD Version 1 N.2/3—12 Jul 2002

23 May 2002: Adjusting the Needle Valve on the Dehumidifier Unit More...

To set the flow control needle valve on the DHU when used with the TFX head, simply open it all the way and leave it. The internal orifices in the DHU are adequate, so no flow adjustment is needed. Refer to the Dehumidifier Unit (DHU) Installation Procedure.

12 Mar 2002: New Navigational Structure More...

This site has been restructured to fit TechPlanet’s common navigation. If you have any questions or comments about the navigation, please contact TechPlanet feedback. For information about content in this site, please contact Maureen Munroe.

TechPlanet CD Version 1.1— 15 Feb 2002

15 Feb 2002: Scripts available for the TFX Head More...

This zip file contains sd series, manual focus series, tint series, and head power series scripts. Download it here or from the Downloads page.

15 Feb 2002: New Debris Nozzle for TFX Head (ECO C967) More...

A new debris nozzle has been designed which does not need adjustment or maintenance. This ECO covers implementation of the new debris removal nozzle with Morgan cabinets. For details, see FCO C967.

14 Feb 2002: Bracket for Head Diagnostic Cable More...

Machines that are having head focus problems, and are FX35 or earlier, may need to have the head diagnostic cable that is mounted inside the machine grounded. A bracket (57-9559A) is available to attach the diagnostic cable to the power box. Refer to the Installing the Diagnostic Cable Bracket procedure for details.

06 Dec 2001: Media Setup Procedures Updated More...

The media setup procedures have been updated and are available on the TFX Head Procedures page. If you are not familiar with TFX Head setup procedures, use the ThermoFlex Media Setup Procedure in conjunction with the Media specific Technical Notes. More experienced CSEs can use the Media specific Technical Notes only.

19 Nov 2001: New TFX Troubleshooting Document Posted More...

Download the document from the Troubleshooting page.


13 Aug 2001: Solve Focus Problems Using the FOC LEARNGAIN Parameter
The FOC LEARNGAIN parameter controls the speed and stability of the focus learning system. When we are learning focus, we multiply the error by the FOC LEARNGAIN parameter. This allows us to more quickly arrive at the correct lens position. However, if the gain is too large, then we can encounter instability, causing the lens position and focus error to oscillate endlessly. Hence, it is important that we find the correct FOC LEARNGAIN value for each device, ensuring fast and stable focus learning.
We typically use a default FOC LEARNGAIN of 0.035 with TFX firmware 1.04. This value has proven to work for most heads in most situations. However, we have occasionally encountered focus errors due to poor FOC LEARNGAIN settings in the TFX head. The focus errors are characterized by two problems:

  1. The plot fails during head stage zero, with the message 'Failed to lock lens at desired position'.
  2. The focus errors on the plot are out of range, oscillating, and becoming worse.
Either of these problems may be intermittent, and you may not see both errors in all cases. In any event, both errors have been solved successfully in the past by changing the FOC LEARNGAIN parameter. In order to adjust the FOC LEARNGAIN parameter, use the following procedure:
  1. In the TFX window, type 'eng' to ensure that you are in engineering mode.
  2. Check the value of FOC LEARNGAIN by typing 'set foc learngain'.
  3. Decrease FOC LEARNGAIN by 0.005 by typing 'set foc learngain < value >'.
  4. Run several plots and determine if the problem is still present.
  5. If the problem is still present, repeat steps 3 & 4. Do not, however, decrease FOC LEARNGAIN below 0.015.
If adjusting FOC LEARNGAIN does not solve your problem, there may be other set-up issues. Remember, decreasing FOC LEARNGAIN will slow the focus learn process, so you should not attempt this unless you have observed problems using the device.

05 Oct 2000: Media Setup procedures for BASF,MacDermid and Asahi
Media setup procedures have been posted for BASF (Digiflex), Asahi (AFP) and MacDermid (Flex-Light). These procedures are for setup on the TFX head only. Go to the Procedures page to access these documents.

28 Jul 2000: Media Setup procedures for Volcano and Cyrel
Media setup procedures have been posted for Kodak DITF (Volcano) and Dupont Cyrel. These procedures are for setup on the TFX head only. Go to the Procedures page to access these documents.

10 Jul 2000: Procedure for replacing the TFX Thermal Head window
A Window Cleaning or Replacement Procedure (72-3458A) has been added to the Procedures page.

24 Jul 2000: Procedure for installing the TFX Thermal Head
TFX Head Installation on ThermoFlex Wide procedure has been added to the Installation page (draft version).

For older news items please refer to previous versions of the Technical Library CDs.