Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Thermal 2 Errorcode: [02517] A data overflow has been detected

Error details | Troubleshooting information

Thermal2 Errorcode: [02517] A data overflow has been detected
Thermal2 Errorcode
[02517] A data overflow has been detected

Service Information A hotlink overflow has been detected. Either the exposure head has attempted to read data from the input buffer before the input buffer is ready or the hotlink attempted to write data to the input buffer when the input buffer was full. If this error occurs while plotting, plot quality may have been compromised.

Note that this error code is also returned to the host as an unsolicited warning fault.

Operator Action Call service.

Causes
  • The exposure head attempted to read data from the input buffer before the input buffer was ready.
  • The hotlink attempted to write data to the input buffer when the input buffer was full.
  • The hotlink and stroke clock are out of sequence.

Applies to: THERMAL2
Modified: Wed Aug 29 16:03:36 2007
Updated: Thu Jul 17 02:31:37 2008
Module: LVD

Troubleshooting information


Possible cause

 

Either the exposure head has attempted to read data from the input buffer before the input buffer was ready, or the hotlink attempted to write data to the input buffer when the input buffer was full.


Suggested action

 
  1. If you are running head firmware v1.05c or 1.05d, check that the hotlink cable is connected and undamaged.
  2. If available, perform a data link test.
  3. Check any other error messages during plotting.
  4. This may indicate problems with the MCE or MPE.

Related Procedure(s)

 

Warning fault 02517 "A data overflow has been detected" occurs when the hotlink cable is disconnected