Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Thermal 2 Errorcode: [03561] The data cable is not detected

Error details | Troubleshooting information

Thermal2 Errorcode: [03561] The data cable (hotlink/coax cable) is not detected
Thermal2 Errorcode
[03561] The data cable (hotlink/coax cable) is not detected

Service Information The data cable has not been detected.

As a result of the shutdown fault, the system fault handler will shutdown the exposure head. Note that this error code is also returned to the host as an unsolicited shutdown fault.

Operator Action Verify the data cable.

Causes
  • The hotlink cable is faulty or disconnected.

Related Documents COMMAND: sys fault [<point> (on|off)]
ERRORCODE: [03563] All faults have been cleared

Applies to: THERMAL2
Modified: Fri Apr 20 13:24:45 2007
Updated: Thu Jul 17 02:31:36 2008
Module: SYS

Troubleshooting information


Possible cause

 

Indicates that the hot link cable may be disconnected


Suggested action

 

Check that the hot link cable is properly connected.


Related Procedure(s)

 

 


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.