Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Thermal 2 Errorcode: [03559] The +40V is out-of-range

Error details | Troubleshooting information

Thermal2 Errorcode: [03559] The +40V is out-of-range
Thermal2 Errorcode
[03559] The +40V is out-of-range

Service Information A +40 volt fault has been detected. The +40 volt supply must be within +38.00 to +42.00 volts ( 5% ).

As a result of the fatal fault, the system fault handler will shutdown the exposure head. Note that this error code is also returned to the host as an unsolicited fatal fault.

Operator Action Call service.

Causes
  • A +40 volt fault has been detected.

Related Documents COMMAND: sys fault [<point> (on|off)]
ERRORCODE: [03563] All faults have been cleared

Applies to: THERMAL2
Modified: Fri Apr 20 13:24:45 2007
Updated: Thu Jul 17 02:31:35 2008
Module: SYS

    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.