Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Thermal 2 Errorcode: [03523] System parameter(s) have been disabled

Error details | Troubleshooting information

Thermal2 Errorcode: [03523] System parameter(s) have been disabled
Thermal2 Errorcode
[03523] System parameter(s) have been disabled

Service Information System parameters are the parameters in the exposure head that the host can read and / or write.

Normally when the host writes a system parameter, the exposure head will write the system parameter as required. For testing purposes, the user can configure the exposure head to ignore the host writes of specific system parameter(s) and instead use private NVS parameter(s). This error code is an informational message ( generated during initialization of the exposure head ) reminding the user that host writes of at least one system parameter are being ignored by the exposure head.

Note that this error code is also returned to the host as an unsolicited warning fault.

Operator Action None, this is an informational message only.

Causes
  • Host writes of at least one system parameter are being ignored by the exposure head.

Related Documents COMMAND: sys parm access <index> (disable|enable)
COMMAND: sys parm [<index> <value>]

Applies to: THERMAL2
Modified: Fri Apr 20 13:24:45 2007
Updated: Thu Jul 17 02:31:36 2008
Module: SYS