Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Checking the beam steering hold current on a TH2 head


Product

 

Thermal 2 head


Background

 

If an incorrect value for the BPD holding current is used, the system will take longer to settle. This may cause a time out.


Procedure

 

The BPD hold current needs to be updated.

  1. Type the commands:
    >> BPD mode on
    >> BPD stream on
  2. Turn the laser on using the command ldd mode current 18.
    DANGER: Follow all necessary laser safety procedures.
  3. Wait 2 to 3 minutes.
  4. Type TH2 >bpd mode update
  5. Type bpd stream off
    Note: This changes the value of holding current to the correct value.

See also

 
  • View a sample of the code readout for these commands.

Technical contact(s)
 

Content owner: Kyle Good
See the Escalation page for escalation contacts.


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.