Troubleshooting safety loop errors
[03553]"Safety loop fault has been detected" and [03573]"A safety loop fault is preventing normal operation"


Product

 
  • Thermal 2 head
  • Lotem® Quantum

Background

 

Use this procedure if errors [03553] or [03573] occur. These errors may have different causes.

Note: If a WLP burst error occurs, see Troubleshooting WLP burst errors.


Requirements

 

Procedure

 

The safety lines in a thermal 2 head require 24 volts. Normally the output device provides this voltage. This voltage is interrupted when a door or panel is opened or when a safety condition is broken.

You must differentiate between an expected safety loop interruption and a faulty element. Faulty elements may be:

  • 24-V power supply
  • Interlock switches
  • Interlock board
  • Relays
  • Cable to the head
  • Thermal 2 head

Use the flowcharts to troubleshoot this problem.


Flowcharts

 

Tip: Click on the images to view the full-size flowcharts. To print this page, adjust the Page Layout to Landscape.


   


See also

 

Technical contact(s)
 

Content owner: Doug Jeffery
See the Escalation page for escalation contacts.