Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
Product |
Thermal 2 Head | ||
Machines affected |
|
||
Error |
EH.PWR signal is unavailable on some Thermal 2 heads. |
||
Symptoms |
On some systems, the absence of this signal will cause a flag, such as Exposure Head Power, to be asserted. If this flag is asserted and is not masked it will generate an error message.
On the MCE Quantum system, the error will be " |
||
Cause |
This signal is a +5V level that is sent from the exposure head back to the MPE/MCE to tell the device that the head has power applied. It is generally not used. Although the EH.PWR signal is present on all heads produced now, there are several hundred in the field that do not have this signal. |
||
Solution |
On systems where the Procedure: MPE-Based Trendsetter NEWS:
Lotem Quantum:
|
||
Technical contact(s) |
|||
Submitted by |
|||
Date submitted |
17 Jun 2002 |
||