Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Thermal 3 Errorcode: [04414] The beam-pointing actuator is saturated

Error details

Thermal3 Errorcode: [04414] The beam-pointing actuator is saturated
Thermal3 Errorcode
[04414] The beam-pointing actuator is saturated

Service Information While attempting to track the write laser(s), the beam-pointing control loop has found that the piezo voltage for the beam-pointing actuator is saturated. As a result of this error, a fatal fault will be generated if the beam-pointing control loop fails to settle within 5 seconds. As a result of the fatal fault, the beam-pointing driver is shutdown and the system fault handler will shutdown the exposure head. Note that this error code is also returned to the host as an unsolicited fatal fault.

After the beam-pointing control loop has settled, a warning fault will be generated on a single occurence. Note that this error code is also returned to the host as an unsolicited warning fault.

Operator Action Call service.

Causes
  • The piezo voltage for the beam-pointing actuator is saturated.

Related Documents COMMAND: bpd on (dual|a|b)

Applies to: THERMAL3
Modified: Wed Jul 16 04:28:29 2008
Updated: Wed Jul 16 04:52:20 2008
Module: BPD

    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.