Thermal 3 Errorcode: [04415] The beam-pointing controller is unstable

Error details

Thermal3 Errorcode: [04415] The beam-pointing controller is unstable
Thermal3 Errorcode
[04415] The beam-pointing controller is unstable

Service Information While attempting to track the write laser(s), the beam-pointing control loop error has exceeded three microns. During initialization of the beam-pointing control loop, a fatal fault will be generated if the beam-pointing control loop fails to settle within 5 seconds. As a result of the fatal fault, the beam-pointing driver is shutdown and the system fault handler will shutdown the exposure head. Note that this error code is also returned to the host as an unsolicited fatal fault.

After the beam-pointing control loop has settled, a warning fault will be generated if the beam-pointing control loop goes unstable for 0.2 seconds. Note this error code is also returned to the host as an unsolicited warning fault.

Operator Action Call service.

Causes
  • The tracking error is exceeding three microns.

Related Documents COMMAND: bpd on (dual|a|b)

Applies to: THERMAL3
Modified: Wed Jul 16 04:28:29 2008
Updated: Wed Jul 16 04:52:16 2008
Module: BPD