Thermal 3 Errorcode: [04411] The sample data is preventing a linear fit

Error details

Thermal3 Errorcode: [04411] The sample data is preventing a linear fit
Thermal3 Errorcode
[04411] The sample data is preventing a linear fit

Service Information Setup of the beam-pointing controller(s) includes an algorithm to acquire A/D samples while either increasing or decreasing the piezo voltage. The resulting sample data should be linear in nature and can be used to calibrate a variety of parameters. This error indicates that a linear fit cannot be calculated for the sample data acquired from the beam-pointing sensors.

Operator Action Call service.

Causes
  • Insufficient signal from the beam-pointing sensors.
  • A hardware failure is corrupting the A/D samples.
  • Firmware error that will occur during firmware development and testing.

Related Documents COMMAND: bpd setup [(a|b)]
COMMAND: bpd characterize [(a|b)]
COMMAND: bpd cal diffsensor

Applies to: THERMAL3
Modified: Wed Jul 16 04:28:29 2008
Updated: Wed Jul 16 04:52:20 2008
Module: BPD