Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Thermal 3 Errorcode: [05217] The laser power is unstable

Error details

Thermal3 Errorcode: [05217] The laser power is unstable
Thermal3 Errorcode
[05217] The laser power is unstable

Service Information While attempting to maintain the laser power, the laser power control loop error has exceeded one percent. During initialization of the laser power control loop, a fatal fault will be generated if the laser power control loop fails to settle within 10 seconds. As a result of the fatal fault, the laser diode driver is shutdown and the system fault handler will shutdown the exposure head. Note that this error code is also returned to the host as an unsolicited fatal fault.

After the laser power control loop has settled, a warning fault will be generated if the laser power control loop goes unstable for 0.1 seconds. Note this error code is also returned to the host as an unsolicited warning fault.

Operator Action Call service.

Causes
  • A hardware failure is corrupting the A/D samples.

Related Documents COMMAND: ldd cal (dual|a|b) <setpoint>
COMMAND: ldd on (dual|a|b) <setpoint>
COMMAND: ldd on man (dual|a|b) <setpoint>

Applies to: THERMAL3
Modified: Wed Jul 16 04:28:35 2008
Updated: Wed Jul 16 04:52:19 2008
Module: LDD