Thermal 3 Errorcode: [05215] The laser power signal level is invalid

Error details

Thermal3 Errorcode: [05215] The laser power signal level is invalid
Thermal3 Errorcode
[05215] The laser power signal level is invalid

Service Information While attempting to maintain the laser power, the laser power control loop has found that there is insufficient signal from the laser diode sensor. As a result of this error, a fatal fault will be generated from a single occurence. As a result of the fatal fault, the laser diode driver is shutdown and the system fault handler will shutdown the exposure head. Note that this error code is also returned to the host as an unsolicited fatal fault.

Note that before initiating the laser power control loop, the laser current is ramped to the estimated setpoint. As a result, a single occurrence of this error will trigger the fatal fault.

Note that after the laser

Operator Action Call service.

Causes
  • Insufficient signal from the laser power sensor.
  • A hardware failure is corrupting the A/D samples.

Related Documents COMMAND: ldd cal (dual|a|b) <setpoint>
COMMAND: ldd on (dual|a|b) <setpoint>
COMMAND: ldd on man (dual|a|b) <setpoint>

Applies to: THERMAL3
Modified: Wed Jul 16 04:28:35 2008
Updated: Wed Jul 16 04:52:15 2008
Module: LDD

    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.