Thermal 3 Errorcode: [06803] The trigger configuration is invalid

Error details

Thermal3 Errorcode: [06803] The trigger configuration is invalid
Thermal3 Errorcode
[06803] The trigger configuration is invalid

Service Information The monitor command lga config (lvdu|lvdl) <offset> <holdoff> <mask> <match> will update the trigger configuration of the logic analyzer. This error code indicates the trigger configuration is invalid.

Operator Action Verify the previous monitor command and enter a valid trigger configuration.

Causes
  • The trigger offset is greater than 100%.
  • The trigger holdoff exceeds the holdoff width.
  • The trigger mask exceeds the probe width.
  • The trigger match exceeds the probe width.

Related Documents COMMAND: lga config (lvdu|lvdl) <offset> <holdoff> <mask> <match>
COMMAND: lga info (lvdu|lvdl)

Applies to: THERMAL3
Modified: Wed Jul 16 04:28:36 2008