Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Thermal 3 Errorcode: [05402] The step response has failed

Error details

Thermal3 Errorcode: [05402] The step response has failed
Thermal3 Errorcode
[05402] The step response has failed

Service Information The automatic tuning of the PID controller analyzes the step response of the PID controller. This error indicates the calculated parameter(s) are invalid.

Operator Action Call service.

Causes
  • The apparent dead time of the PID controller is negative.
  • The controllability factor of the PID controller indicates the PID controller can't be tuned.

Related Documents COMMAND: bpd tune [(a|b|c)]
COMMAND: ldd tune

Applies to: THERMAL3
Modified: Wed Jul 16 04:28:36 2008
Updated: Wed Jul 16 04:52:17 2008
Module: MAT

    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.