Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Thermal 3 Errorcode: [06208] The combination data is invalid

Error details

Thermal3 Errorcode: [06208] The combination data is invalid
Thermal3 Errorcode
[06208] The combination data is invalid

Service Information The monitor command plt combination config <index> <combination> <name> <number> is used to configure the number of stripes of the combination data and then the monitor command plt combination init <index> <stripe> <pattern> <width> is used to initialize each stripe of the combination data.

Operator Action Verify the previous monitor command and enter valid combination data.

Causes
  • The copy index is greater than 3.
  • The TPG combination is greater than 65535.
  • The combination name is greater than or equal to 40 characters.
  • The stripe number is less than 2 or greater than 64.
  • The stripe index is greater than 63.
  • The stripe pattern is a TPG combination.
  • The stripe pattern does not exist.

Related Documents COMMAND: plt combination config <index> <combination> <name> <number>
COMMAND: plt combination init <index> <stripe> <pattern> <width>

Applies to: THERMAL3
Modified: Wed Jul 16 04:28:37 2008
Updated: Wed Jul 16 04:52:19 2008
Module: PLT