Thermal 3 Errorcode: [06207] The pattern data is invalid

Error details

Thermal3 Errorcode: [06207] The pattern data is invalid
Thermal3 Errorcode
[06207] The pattern data is invalid

Service Information The monitor command plt pattern config <index> <pattern> <name> <row> <repeat> <column> is used to configure the dimensions of the pattern data and then the monitor command plt pattern init <index> <row> <nibbles> is used to initialize each row of the pattern data. This error indicates that the pattern data is invalid.

Operator Action Verify the previous monitor command and enter valid pattern data.

Causes
  • The copy index is greater than 3.
  • The TPG pattern is greater than 65535.
  • The pattern name is greater than or equal to 40 characters.
  • The row number is 0 or greater than 16.
  • The row repeat is 0 or greater than 16.
  • The column number is 0 or greater than 16.
  • The row index is greater than 15.
  • The pattern string has an invalid character.
  • The pattern string is an invalid length.