Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Thermal 3 Errorcode: [02010] The parameter element is invalid

Error details

Thermal3 Errorcode: [02010] The parameter element is invalid
Thermal3 Errorcode
[02010] The parameter element is invalid

Service Information When the parameter subsystem registers the table of parameters from other subsystems, the number of elements for each parameter can also be specified. This error indicates that the user has specified an invalid element.

If the subsystem specifies one element for one of the parameters, the user must not specify the element when accessing the parameter. For example, the light valve driver subsystem specifies one element of the stroke offset parameter. Thus the user must not specify the element.

If the subsystem specifies multiple elements for one of the parameters, the user must specify the element when accessing the parameter. For example, the media subsystem specifies 120 elements for the stroke table. Thus the user will specify elements from 0 to 119.

Operator Action Verify the previous monitor command and enter a valid element.

Causes
  • The element is invalid.

Related Documents COMMAND: set <subsystem> [<copy>] <parameter> [(<element>|all)] <value>

Applies to: THERMAL3
Modified: Wed Jul 16 04:28:38 2008
Updated: Wed Jul 16 04:52:19 2008
Module: PRM

    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.