The exposure head will monitor a variety of satellite faults ( voltages, communications, etc ) and shutdown the exposure head if required. To allow operation of the exposure head to continue, the user can mask any combination of satellite faults to prevent the exposure head from being shutdown. This error code indicates that the launching of a plot has either been prevented or would be prevented by a satellite fault.
|
|
| It is undesireable to mask satellite faults. Masking a satellite fault implies that there is a hardware failure in the exposure head. Regardless, the underlying problem should be fixed; not masked.
|
|
| Note that the monitor command sat status will display the satellite faults and the monitor command sat mask (on|off) <index> will configure the fault mask's.
|
Verify all satellite faults in the exposure head. If necessary, a satellite fault can be masked in the exposure head.
|
- System monitoring of the satellite faults has detected as least one fault in the exposure head.
|
COMMAND: sat status
|
|
|
COMMAND: sat mask [(on|off) <index>]
|