Hardware Installation - E30
Connecting to an Imagesetter
Connecting an Imagesetter
Verifying Dip Switch
Settings
Connecting to an Improofer
Connection to an Imagesetter is through a fiber optic cable and the SFL card on the Brisque.
For the VLSI Class II board (Cat# 503D40259), the dip switches should be set as follows: |
Installed in Imagesetter U311 On: 4, 5, 6, 8 Off: 1, 2, 3, 7
U314 On: 2, 3, 4, 5, 6, 7, 8 Off: 1
Dip Switches with no change U1515
(4 switch)On: 2 Off: 1, 3, 4
U1308A
(4 switch)On: 1 Off: 2, 3, 4
For VSLI Class Board (Cat# 503D38691) the dip switches should be set as follow: |
Installed in Imagesetter U906 On: 2, 3, 4, 5, 6, 7, 8 Off: 1,
U311 On: 4, 6, 7 Off: 1, 2, 3, 5, 8
U1403 On: none Off: 1, 2, 3, 4, 5, 6, 7, 8
|
Refer to CreoScitex Doc# 771-50636A, CreoScitex Improof Installation and User Guide. |