Background
|
|
The firmware that is currently installed in Qualstar AIT-2 tape libraries
and in Sony AIT-2 SCSI tape drives is not compatible with one another.
As a result, the following problems can occur when you use the LEGATO
NetWorker® application:
- You cannot unload Sony AIT-2 SCSI tapes and error 69 appears.
- A Sony AIT-2 SCSI tape drive becomes disabled.
This procedure describes how to change the existing firmware on both
a Qualstar AIT-2 library and a Sony AIT-2 SCSI drive, which prevents the
problems mentioned earlier from occurring.
|
Requirements
|
|
Qualstar AIT-2 tape library firmware version 2.18,
TLS LIB FW2.18 upgrade:
- Executive Board III PCB (Creo p/n 609-00044)
- Executive Board IV PCB (Creo p/n 609-00045)
Sony AIT-2 SCSI tape drive version 0.1F firmware,
AIT-2 DRV FW 010F UPDATE TAPE (FCO)* (Creo p/n 610-00012)
|
Procedure
|
|
To determine which firmware to order, check the current firmware version
and the Executive Board Level of the Qualstar AIT-2 tape library:
- At the AIX command line prompt, navigate to the directory /etc/LGTOuscsi/.
- Type
inquire -c and then press Enter.
- On the front panel of the Qualstar AIT-2 tape library, press the Menu
button.
- Press the down arrow button to navigate to the Maintenance
menu and press
Enter.
- Press the down arrow button twice to navigate to Display
Revision and press
Enter.
The following is an example of the information that appears onscreen:
- Date : 12/06/2003
- Part Number :700115 (Executive Board IV)
Or,
- Part Number :700105 (Executive Board III)
- Revision : 2.18 (firmware version)
To change firmware on a Qualstar AIT-2 tape library:
- From the Qualstar AIT-2 tape library PCB Executive III or PCB Executive
Board IV, remove the existing U4 firmware chip.
- For a Qualstar AIR tape library PCB Executive III, install the new
firmware chip TLS LIB FW2.18 upgrade (Creo p/n 609-00044).
For a Qualstar AIR tape library PCB Executive IV, install the new firmware
chip TLS LIB FW2.18 upgrade (Creo p/n 609-00045).
- Reconfigure the Qualstar AIT-2 tape libraryfollow the steps
provided in the Solution section of Qualstar
Tape Library Lost Configuration.
To change firmware on a Sony AIT-2 SCSI drive:
- Shut down Brisque, Brisque Serve or Timna server.
- Shut down, and then start up the Qualstar AIT-2 library.
- Open the library door.
- In the top drive of the Sony AIT-2 SCSI drive, insert the firmware
tape
AIT-2 DRV FW 010F UPDATE TAPE (FCO)* (Creo p/n 610-00012).
While the firmware loads, the drives three LEDs flash for approximately
seven seconds, and flash once again for approximately two seconds when
the drive is verifying the firmware.
The entire firmware loading process takes approximately three minutes
to complete. When it is finished, the firmware tape ejects automatically.
- For each of the remaining Sony AIT-2 SCSi tape drives, repeat steps
3 and 4.
- When all firmware has been loaded onto the tape drives, shut down
and then start up the Qualstar AIT-2 tape library.
- Reboot Brisque, Brisque Serve or Timna.
- To verify that the Qualstar AIT-2 tape library and all Sony AIT-2
SCSI tape drives have the new firmware versions loaded:
- At the AIX command line prompt, navigate to the directory /etc/LGTOuscsi/.
- Type
inquire -c and then press Enter.
- Return the firmware tape FW 010F (Creo p/n 610-00012) to stock.
|